When warm, dry unsaturated air is pulled through a watersoaked pad, water is evaporated and is absorbed as water vapor into the air. The first of these, the directcontact or open cooling tower figure 3, ex poses water directly to the cooling atmosphere, thereby transferring the source heat load directly to the air. A typical recirculation cycle for the desiccant cooling system is shown in figure 21 b. Examples of how to use evaporative in a sentence from the cambridge dictionary labs. On the other hand, the indirect cooling method allows industrial spaces, restaurants or other businesses to cool their spaces to temperatures that are lower than those offered by portable swamp coolers like cool boss. View evaporative cooling research papers on academia. Evaporative cooling is a reliable, lowtech method to provide cooler air during hot weather. Evaporative cooling pads that are saturated with water, a substantial cooling effect is realized due to the evaporation of that water. Installing an evaporative cooling system is an alternative method of using an air conditioning system that pumps refrigerant through compression and evaporative cycles.
Jul 02, 2014 drawbacks of evaporating cooling system. The second type, often called a closedcircuit cooling tower, involves. Evaporative cooling practical action 3 any part of the country using locally available materials. International journal of engineering research and general. What are the advantages and disadvantages of evaporative cooling.
Energies free fulltext thermal performance evaluation of. Evaporative cooling an overview sciencedirect topics. At the point when considering evaporative cooling, one ought to figure out the wet knob and dry globule temperatures of the region. Indirect evaporative cooler westaire engineering inc. Select air cooled or evaporative condensers, cooling. Introduction to air conditioning systems ced engineering. The evaporative cooling module shall be selfcontained. Stainless steel integral cooling tower with submersible type pump. In other words, at these temperatures, windchill effect alone was adequate to get good performance if air velocity was high enough.
To describe the liquid gas interface for say a substance x, we must use the concept of vapour pressure. Evaporative cooler engineering specification 598 1. Types of evaporative cooling evaporative cooling works by employing waters large. A widespread utility system in industry is an induced draft evaporative cooling tower. It takes heat energy to change the water or any liquid from a liquid into a vapor. Evaporative cooling evaporative cooling is a very efficient means of heat dissipation, as one litre evaporated sweat removes 672 wh from the body at a temperature of 35 c. Evaporative cooling is based on the thermodynamics of evaporation of water, i. Direct and indirect evaporative cooling strategies. Water can absorb a lot of heat without changing phases, allowing it to remove heat. The systems design was based upon the humidifying capacity of an ultrasonic humidifier supplied by a quebec company, plastique frapa inc. The direct cooling under the influence of sinking cold air is accompanied by evaporative cooling, induced by evaporation of moisture from the walls wigley and brown, 1976. The second stage is handled by conventional air conditioning. To evaporate 1kg of water into an atmosphere, 680w of energy is required.
Fan and pad greenhouse evaporative cooling systems. Applied air offers direct evaporative cooling equipment with air deliveries from 3,000 cfm to 64,000 cfm and indirect or indirectdirect evaporative cooling. As air is drawn through this, cascading water provides evaporative cooling, similar to an open cooling system, except that the cooled water is never allowed to make direct contact with the air. It is not successful in the areas where the dampness is high. Dristeem evaporative cooling and humidification systems 3 how do first costs and energy costs of evaporative cooling systems compare. Course contents evaporative coolers, often called swamp coolers, are cooling systems that use only water and a blower to circulate air. Evaporative cooling can be integrated into freshairhandling units, to reduce cooling demand. The indirect evaporative section also incorporates a scavenger fan to exhaust air through the pipes, a water distribution system which includes a water pump and spray nozzles to provide a uniform distribution over the entire heat exchanger, and a filter section to clean and maintain incoming air into the system. Matthaios santamouris, in minimizing energy consumption, energy poverty and global and local climate change in the built environment. Use these systems for applications where several spaces with uniform loads will be served by a single apparatus and where precision control of the environment is required. In a direct evaporative cooler, a blower forces air through a permeable and watersoaked pad. Pdf design and construction of an evaporative cooling. Types of cooling towers two basic types of evaporative cooling devices are used.
The temperature of dry air can be dropped significantly through the phase transition of liquid water to water vapor, which requires much less energy than. Biggest problem facing the indirect evaporative cooling iec technology lies in its high level of dependency to ambient air condition. A cooling tower is typically used to cool down water that has been heated due to airconditioning condensing or an industrial process. Direct evaporative cooling open circuit direct evaporative cooling introduces water directly into the supply airstream usually with a spray or some sort of. There are two broad types of evaporative coolers available on the market, direct and indirect, both commonly known as twostage. This phase change requires energy, which is called latent heat of evaporation this is the energy required to change a substance from liquid phase to the gaseous one without temperature change. Applied air offers direct evaporative cooling equipment with air deliveries from 3,000 cfm to 64,000 cfm and indirect or indirectdirect evaporative cooling units with air deliveries from 1,500 cfm to 37,500 cfm. In summary, evaporative cooling is the process of removing heat from a surface due to the evaporation of water.
However, when the desiccant cooling system must handle the entire load, it overdries the process air so evaporative cooling can be used for the sensible cooling. Suited for virtually all geographic locations, the. Cooling coils can be direct expansion or chilled water. For steam humidifiers, this energy typically comes from the electricity or gas being used to boil the water. The principle of evaporative cooling can be used in different ways.
Cooling is achieved because of the extraction of the evaporation latent heat from the. A cooling tower is a heatrejection device, which discharges warm air from the cooling tower to the atmosphere through the cooling of water. Another indirect cooling tower system involves a separate heat exchanger and an open cooling tower. If youre seeing this message, it means were having trouble loading external resources on our website. Evaporative cooling design guidelines manual iv this report by nrg engineering is funded by the new mexico energy minerals and natural resources department, 1220. How free is evaporative cooling in the data center green. Evaporative cooling, effectiveness, performance, energy saving. Analysis of advanced solar hybrid desiccant cooling. Cooling through evaporation is the natural occurrence. Utility processes in industry are suited for this, having a large thermal time constant or buffer, and large electricity consumption. The water is moved towards the cooling tower through a series of pipes.
The cooling effects of using various modes vapor compression only. Extreme heat and humidity can, and frequently does, cause heat strokes. The shift from fossil fuel to more renewable electricity generation will require the broader implementation of demand side response dsr into the grid. Analysis of advanced solar hybrid desiccant cooling systems. In summer, the air inside the cave is colder and thus heavier than the external one and is trapped inside the cave, hence the name of the phenomenon. The concept and implementation of free cooling dates back millennia, with porous clay vessels full of water placed in rooms, or egyptians and persians using windcatchers, passing the air through subterranean water stores and back into buildings. Every liquid at a given pressure and temperature has a definite value for its vapour pressure. Evaporative cooler types evaporative coolers cool boss. Evaporative cooler, leaving air temperature, relative humidity, performance introduction in direct evaporative cooling, the air to be conditioned comes in direct contact with the wetted surface, and gets cooled and humidified. Evaluation of evaporative cooling systems in industrial buildings article pdf available in international journal of heat and technology 333. The water is then sprayed into multiple material banks through nozzles. Desiccant cooling systems are very good at providing latent cooling by reducing the humidity ratio of building air. In the hvac industry, the term cooling tower is used to describe both open and. A heat section can be added to most models to provide a ventilation unit for year round use.
Used in conjunction with coolair fans, a temperature reduction of 1025 degrees is commonplace. Direct evaporative cooling open circuit direct evaporative cooling introduces water directly into the. This adiabatic cooling process is also used to create the chilled water that feeds our indirect evaporative cooling coil. It is not only uncomfortable to work in, but it can be downright dangerous for the welfare of your workers. Evaporative cooling design guidelines manual iv this report by nrg engineering is funded by the new mexico energy minerals and natural resources department, 1220 south st.
The use of an indirect evaporative cooling system in conjunction with a mechanical ac system o. Evaporative cooling systems use the same principle as perspiration to provide cooling for machinery and buildings. You can duplicate the principle behind direct evaporative cooling by wrapping a wet handkerchief around your neck on a hot day and standing in front of a fan. If youre behind a web filter, please make sure that the domains. This study considers a hybrid freshairhandling unit which incorporates a vaporcompression cooling cycle and indirect evaporative cooling to condition an ambient primary airstream to a desired supply air state.
Highpressure system first costs are generally higher than other adiabatic systems due, mostly, to the cost of adding. The primary responsibility of a business man is to provide the secure and comfortable feeling to the clients who visit their office. During the process of perspiration, it absorbs heat to cool the body. Evaporative cooling design guidelines ced engineering. As the air is passing through the pad, it is filtered and cooled as well as humidified. It will consist of the component parts as listed in the following sections. The indirect evaporative section also incorporates a scavenger fan to exhaust air through the pipes, a water distribution system which includes a water pump and spray nozzles to provide a uniform distribution over the entire heat exchanger, and a filter section to. One may wonder when does evaporative cooling occur. Furnish proof satisfactory to the owner or his representative, of. The main disadvantage of this kind of particular cooling is that it is only applicable in dry atmospheres. Munters systems use coolingheat rejection strategies that achieve a.
Energies free fulltext thermal performance evaluation. Matlab based design software for greenhouse evaporative cooling system wei fang dept. Waterbased evaporative cooling technologies have been used for many centuries to provide comfort in cities. Evaporative cooling occurs when air, that is not too humid, passes over a wet. Many households use conventional cooling systems as a backup to their evaporative cooling systems during these periods. Processes free fulltext performance assessment of a. Supply, installation and commissioning of evaporative type air cooling system along with accessories qty 06 nos. A direct evaporative cooling system is the simplest and most popular evaporative cooling system available. With oasis, the energy required to remove heat is significantly reduced. When low output is required, the pumpmotor is turned. Performance evaluation for indirect evaporative cooling etsce7 southern california edison page iii emerging products june 2015 abbreviations and acronyms 6 cooling capacity, enthalpy flow rate e. Direct evaporative cooling is an adiabatic process where the dry bulb temperature is lowered without changing the amount of heat idec dec dec idec in the air.
Fan and pad greenhouse evaporative cooling systems 3 area covered by plants, and floor material i. Ashrae american society of heating, refrigerating, and airconditioning engineers publishes specifi c guidelines for temperature and humidity control within data centres. Types of evaporative coolers direct evaporative coolers use a fan to pull outside air through media pads that are kept. The roof configuration can also influence the temperature increase. A concept of an evaporative cooling utilized with the help of maisotsenko cycle. Evaporative cooling is a physical phenomenon in which evaporation of a liquid, typically into surrounding air, cools an object or a liquid in contact with it.
Evaporative cooling can be further classified as follows fig. This slows down the waters flow as it moves through the cooling tower. When temperatures go above the mid80s, you definitely need the additional real temperature drop from evaporative cooling to keep birds growing. The basic structure of the cooling chamber can be built from bricks and river sand, with a cover made from cane or other plant material and sacks or cloth. The most common example in human is the process of perspiration. Duan, zhiyin 2011 investigation of a novel dew point. Anyone who has spent some time in a hot, stuffy warehouse understands how torturous heat and humidity can be. Suited for virtually all geographic locations, the coolair evaporative cooling system.
78 958 710 585 896 162 1158 494 1231 875 633 1456 489 254 512 749 779 1636 429 946 1159 994 1122 554 230 1025 360 1445 124 891 212 678